航空学报 > 2026, Vol. 47 Issue (8): 132710-132710   doi: 10.7527/S1000-6893.2025.32710

机动载荷下振动对涡轮叶尖气热特性影响

汪翔宇, 陈显赟, 刘梦琪, 丰镇平()   

  1. 西安交通大学 能源与动力工程学院,西安 710049
  • 收稿日期:2025-08-26 修回日期:2025-09-15 接受日期:2025-10-27 出版日期:2025-11-04 发布日期:2025-11-03
  • 通讯作者: 丰镇平 E-mail:zpfeng@xjtu.edu.cn
  • 基金资助:
    国家科技重大专项(2019- Ⅱ -0008-0028)

Influence of vibration on aerothermal characteristics of turbine blade tips under maneuvering loads

Xiangyu WANG, Xianyun CHEN, Mengqi LIU, Zhenping FENG()   

  1. School of Energy and Power Engineering,Xi’an Jiaotong University,Xi’an 710049,China
  • Received:2025-08-26 Revised:2025-09-15 Accepted:2025-10-27 Online:2025-11-04 Published:2025-11-03
  • Contact: Zhenping FENG E-mail:zpfeng@xjtu.edu.cn
  • Supported by:
    National Major Science Technology Project of China (2019- Ⅱ -0008-0028)

摘要:

为探究机动载荷引发的高压涡轮转子振动对其动叶凹槽叶尖气动和换热特性的影响,采用数值模拟方法对振动影响下无气冷和气冷凹槽叶尖的时均和瞬态气热性能进行了对比分析。振动对时均特性影响有限:无气冷叶尖振动工况下平均总压损失系数较无振动工况下下降0.2%(由0.094 6降至0.094 4),面平均换热系数波动小于0.2%;气冷叶尖振动工况下平均总压损失系数较无振动工况下下降3.8%,面平均换热系数下降0.8%。瞬态特性分析表明:无气冷叶尖的瞬时泄漏流量、面平均总压损失系数和换热系数均与振幅呈正相关,凹槽底面10%~70%轴向弦长及肩壁顶面10%~60%轴向弦长区域的换热系数对振幅变化敏感;气冷叶尖在冷气掺混与振动的共同作用下,涡系强度增大、气动损失波动加剧、凹槽底面换热不均匀性增强,其中尾缘肩壁顶面换热系数受振动影响显著且冷气难以覆盖,在设计中应重点关注。

关键词: 高压涡轮, 转子振动, 涡轮叶片, 气动特性, 换热特性

Abstract:

In order to investigate the influence of high-pressure turbine rotor vibration caused by dynamic load on the aerodynamic and heat transfer characteristics of the rotor blade tip with grooves, the time-averaged and transient aerodynamic and thermal performance of the non-air-cooled and air-cooled grooved blade tips under the influence of vibration were compared and analyzed by numerical simulation method. The influence of vibration on the time-averaged characteristics is limited. The average total pressure loss coefficient under the condition of no air-cooled blade tip vibration is 0.2% lower than that without vibration (from 0.094 6 to 0.094 4), and the fluctuation of the surface average heat transfer coefficient is less than 0.2%. For the air-cooled blade tip vibration condition, the average total pressure loss coefficient is 3.8% lower than that without vibration, and the surface average heat transfer coefficient is reduced by 0.8%. The transient characteristics analysis shows that the instantaneous leakage flow rate, the surface average total pressure loss coefficient and the heat transfer coefficient of the air-cooled blade tip are positively correlated with the amplitude. The heat transfer coefficient of the 10%-70% axial chord length at the bottom of the groove and the 10%-60% axial chord length at the top of the shoulder wall is sensitive to the amplitude change. Under the combined action of cooling air mixing and vibration, the strength of the vortex system increases, the fluctuation of the aerodynamic loss increases, and the non-uniformity of the heat transfer at the bottom of the groove increases. Among them, the heat transfer coefficient of the top surface of the trailing-edge shoulder wall is significantly affected by vibration and hardly covered by the coolant, to which should be paid attention in the design.

Key words: high-pressure turbine, rotor vibration, turbine blade, aerodynamic characteristics, heat transfer characteristics

中图分类号: