摘要: 针对变几何涡轮(VGT)静子调节过程中端区间隙非均匀变化及其引起的性能损失问题,以某单级变几何涡轮为研究对象,采用经试验验证的数值方法,开展了真实调节间隙气动影响与分布优化研究。基于导叶实际调节几何获得叶尖和叶根间隙分布,并对理想均匀间隙、等泄漏面积均匀间隙和真实调节间隙进行对比。结果表明,真实间隙使级效率降低0.82%-0.96%,附加损失主要集中于静子叶尖区域;整体泄漏面积增大是效率下降的主要原因,而间隙空间非均匀分布进一步改变泄漏流的产生位置和沿程发展。端区泄漏主要集中于0.5-0.7倍轴向弦长范围。基于上述规律,在满足全调节范围机械安全约束的前提下,通过优化初始间隙分布,降低整体等效间隙并控制泄漏主导区域的局部间隙,优化后各工况级效率提高0.6%-0.78%。研究表明,基于真实调节间隙演化规律的初始间隙分布优化能够兼顾机械安全与气动性能,有效降低端区泄漏损失。

关键词: 变几何涡轮, 真实非均匀间隙, 端区泄漏, 气动性能, 间隙分布优化

Abstract: To investigate the non-uniform endwall clearance formed during variable-geometry turbine (VGT) stator adjustment and its aerodynamic effects, a single-stage variable-geometry turbine was analyzed using an experimentally validated numerical method. Tip and hub clearance distributions were derived from the actual guide-vane adjustment geometry, and three models were compared: ideal uniform clearance, equal-leakage-area uniform clearance, and actual adjustment-induced clearance. The actual clearance reduced stage efficiency by 0.82–0.96 percentage points, with most additional loss occurring in the stator tip region. The increase in overall leakage area was the dominant cause of the efficiency penalty, while the spatial clearance distribution mainly altered the axial location and streamwise development of leakage flow. Leakage was concentrated within 0.5–0.7 axial chord. Based on these findings, the initial clearance distribution was optimized under full-range mechanical safety constraints by reducing the equivalent clearance and controlling the local clearance in the leakage-dominant region. The optimized design increased stage efficiency by 0.60–0.78 percentage points, demonstrating that the proposed method can effectively reduce endwall leakage loss while balancing mechanical safety and aerodynamic performance.

Key words: variable geometry turbine, real non-uniform clearance, endwall leakage, aerodynamic performance, clearance distribution optimization