导航

Acta Aeronautica et Astronautica Sinica

Previous Articles     Next Articles

Thermal Degradation Estimation and Hierarchical Coordinated Control of Electro-Hydrostatic Actuators for Hypersonic Vehicles

Zhao-Xiong WANG1,Li Yunhua2   

  1. 1. Beihang University
    2.
  • Received:2026-07-02 Revised:2026-09-11 Online:2026-09-28 Published:2026-09-28
  • Contact: Li Yunhua

Abstract: To address the degradation of pressure response capability and displacement tracking performance caused by the coupled effects of branch temperature rise, cooling-capacity attenuation, and leakage growth in electro-hydrostatic actuators for hypersonic vehicles under finite heat-sink conditions, an online degradation estimation and hierarchical coordinated control method is proposed. First, a control-oriented reduced-order hydro-mechanical-thermal coupling model of the electro-hydrostatic actuator branch is established, in which the actuator output displacement, output velocity, actuator-cylinder load pressure, and lumped branch temperature are selected as state variables. An effective heat-transfer factor, leakage increment, and actuation capability factor are introduced to characterize the dominant degradation effects under heat-sink-limited conditions. Then, an online degradation estimator is constructed, where the effective heat-transfer factor is updated using the temperature residual, the leakage increment is updated using the pressure residual, and the lumped disturbance caused by mission loads and unmodeled dynamics is estimated through an extended state observer. On this basis, an upper-level heat-sink–performance coordination strategy and a lower-level actuation capability compensation control law are designed. The upper layer allocates heat-sink resources and adjusts the tracking intensity according to the estimated thermal state and cooling capability, whereas the lower layer calculates the motor-pump control input according to the actuation capability factor and disturbance estimate. Simulation results show that, under compound degradation scenarios, the proposed method reduces the root-mean-square displacement tracking error about 9.33%, and limits the maximum temperature to 68.030°C. Low tracking errors are also maintained under thermal-load variations and parameter perturbations. These results demonstrate that the proposed method can ensure both thermal safety and actuation performance of the electro-hydrostatic actuator branch under finite heat-sink conditions.

Key words: electro-hydrostatic actuator, thermal degradation estimation, finite heat sink, hierarchical coordinated control, actuation capability compensation