摘要: 建立了座航两种气密性检验方法的内在联系,可从压降法测试中算出泄漏量,也可从流量法测试中算出压降法的降压时间。为了实际使用方便,还建立了有关图表,供直接查阅。

关键词: 泄漏试验, 座舱, 密封性, 座舱密封

Abstract: There are two kinds of methods for the cabin leakage test: flow-rate method and pressure-drop method.The pressure drop method is simple, but leakage rates can not be directly read out.If leakage rates should be determined,interconversion relationship would te used. In this paper, the interconversion of the two kinds of methods for cabin leakage test is established. Leakage rates can be calculated from the method of pressure drop test, andthe time of pressure drop can be calculated from the method of leakage rates test. The application to cabin leakage test is discussed. The concerned charts are established for practical use.