首页 >

基于RPA探针阵列与推力联合诊断的XHT工作特性研究-空间电推进关键技术专栏

曹加倍1,王亚楠1,周珂辉1,何雨桁1,黄炜鑫1,付瑜亮1,孙安邦2,丁卫东1   

  1. 1. 西安交通大学
    2. 西安交通大学电气工程学院
  • 收稿日期:2026-06-30 修回日期:2026-09-14 出版日期:2026-09-28 发布日期:2026-09-28
  • 通讯作者: 王亚楠
  • 基金资助:
    空间高效能推进技术及应用全国重点实验室基金

Operating Characteristics of XHT Based on Combined RPA Probe Array and Thrust Diagnosis

  • Received:2026-06-30 Revised:2026-09-14 Online:2026-09-28 Published:2026-09-28
  • Contact: Yanan Wang

摘要: 针对低功率外部放电霍尔推力器在微纳卫星应用中的离子加速机制不明及传统单点诊断空间分辨率不足的问题,研制了一套集微推力测量与羽流离子能量角向分布于一体的联合诊断系统。该系统集成了高精度微推力测量台架与环形阵列阻滞电位分析仪,旨在实现对推力器宏观性能与微观羽流特性的原位同步诊断。基于测量数据构建了离子能量-角度分布矩阵,提出了“90%能量集中角”指标,衡量离子能量通量在角向空间的集中程度,为评估推力器束流能量聚焦品质提供依据。建立了从RPA离子能量分布到宏观推力的计算模型,实现了微观诊断结果与宏观推力的校验。结果表明:在阳极电压140 V工况下,该外部放电霍尔推力器输出推力约为3.7 mN,羽流离子最概然能量为116 eV,90%能量集中角为125.6°;在阳极电压220 V工况下,推力约为5.9 mN,羽流离子最概然能量为203 eV,90%能量集中角为102.4°,能量聚焦品质更优,验证了所提指标与关联模型的有效性。

关键词: 霍尔推力器, 外部放电, 微推力测量, 阻滞电位分析仪, 联合诊断, 离子能量分布

Abstract: To address the unclear ion acceleration mechanism and the insufficient spatial resolution of traditional single-point diagnostics for low-power external discharged Hall thrusters in micro/nano-satellite applications, develops a combined diagnostic system that integrates micro-thrust measurement and plume ion energy angular distribution. The system incorporates a high-precision micro-thrust measurement stand and an annular-array retarding potential analyzer (RPA), aiming to achieve in-situ synchronous diagnosis of the thruster’s macroscopic performance and microscopic plume characteristics. Based on the measured data, an ion energy–angle distribution matrix is constructed, and a “90% energy concentration angle” metric is proposed to quantify the concentration of ion energy flux in angular space, providing a basis for evaluating the beam energy focusing quality of the thruster. A computational model linking the RPA ion energy distribution to the macroscopic thrust is established, enabling cross-validation between microscopic diagnostic results and macroscopic thrust. The results show that under an anode voltage of 140 V, the external discharged Hall thruster delivers a thrust of approximately 3.7 mN, a plume ion most probable energy of 116 eV, and a 90% energy concentration angle of 125.6°; under an anode voltage of 220 V, the thrust is about 5.9 mN, the most probable energy is 203 eV, and the 90% energy concentration angle is 102.4°, indicating better energy focusing quality. These findings validate the effectiveness of the proposed metric and the associated correlation model.

Key words: Hall thruster, external discharge, micro-thrust measurement, retarding potential analyzer, combined diagnostic, ion energy distribution

中图分类号: