  • Contact: Pingyang WANG

摘要: 摘 要:碘工质霍尔推力器具有高储存密度、低储存压力和系统小型化潜力,是低功率空间电推进的重要发展方向,但其近场光谱发射受到多组分反应与电子碰撞激发的共同影响。针对低功率碘霍尔推力器,开展了200V/1A、250V/1.2A和300V/1A三组工况下出口下游70 mm范围内的空间分辨光学发射光谱诊断,采用中性碘原子和单电离碘离子的特征谱线表征相应组分的发射响应,并通过下游保持率、发射质心和有效衰减长度定量描述单电离碘离子发射结构的轴向演化。结果表明,250V/1.2A和300V/1A两个相近功率工况具有明显不同的近场发射结构。在通道中径视线上,250V/1.2A工况在出口外20 mm和30 mm处的下游保持率及有效衰减长度分别为300V/1A工况的2.55、2.96和1.89倍,发射质心较后者向下游移动约3.95 mm;300V/1A工况的单电离碘离子发射在通道中径视线上快速衰减,而推力器轴线视线上仍保留部分发射响应,呈现明显的横向发射结构差异。一维碘多组分模型进一步表明,两工况均以原子碘电离作为单电离碘离子的主要生成通道,积分贡献均约为82%。与300V/1A相比,250V/1.2A工况的单电离碘离子总生成源项峰值和轴向积分分别提高约14.4%和9.9%,电子密度和单电离碘离子数密度峰值分别提高约9.9%和20.1%。总生成源项、电子密度和单电离碘离子数密度的峰值位置均向通道出口方向移动,出口处电子密度与单电离碘离子数密度的乘积提高约32.4%。实验与模型结果表明,相近功率下,电压电流组合变化能够改变通道内碘反应区域、单电离碘离子生成强度及出口电子离子状态,这些变化与近场单电离碘离子发射的维持尺度和空间分布差异相对应。

关键词: 碘工质, 霍尔推力器, 光学发射光谱, 流体模型, 等离子体诊断

Abstract: Abstract: Iodine-fueled Hall thrusters are promising for low-power electric propulsion because of their high propellant storage density, low storage pressure, and miniaturization potential, but their near-field emission is jointly influenced by multispecies reactions and electron-impact excitation. Spatially resolved optical emission spectroscopy was performed on a low-power iodine Hall thruster within 70 mm downstream of the exit at 200V/1A, 250V/1.2A, and 300V/1A. Selected neutral and singly ionized iodine lines characterized the respective emission responses, while downstream retention ratios, emission centroids, and effective decay lengths quantified the axial structure of singly ionized iodine emission. The 250V/1.2A and 300V/1A conditions produced distinct near-field emission structures despite similar powers. Along the channel mid-radius sightline, retention ratios at 20 and 30 mm and the effective decay length at 250V/1.2A were 2.55, 2.96, and 1.89 times those at 300V/1A, respectively, with the centroid approximately 3.95 mm farther downstream. At 300V/1A, singly ionized iodine emission decayed rapidly along this sightline but persisted partly along the thruster-axis sightline, indicating pronounced transverse differences. A one-dimensional multispecies iodine model showed that atomic iodine ionization accounted for approximately 82% of the integrated singly ionized iodine production source in both cases. Compared with 300V/1A, 250V/1.2A increased the peak and axial integral of the total production source by approximately 14.4% and 9.9%, respectively, and the peak electron and singly ionized iodine number densities by approximately 9.9% and 20.1%, respectively. The source and both density peaks shifted toward the channel exit, where the product of electron and singly ionized iodine number densities increased by approximately 32.4%. These results indicate that different voltage–current combinations at similar powers modify channel reaction regions, singly ionized iodine production, and exit electron and ion conditions, corresponding to distinct persistence scales and spatial distributions of near-field singly ionized iodine emission.

Key words: iodine propellant, Hall thruster, optical emission spectroscopy, fluid model, plasma diagnostics

中图分类号: