Research on Calculation of Leakage Reactance of Dual Stator-Winding Induction Generator

LIU Ling-shun1,2, HU Yu-wen1, HUANG Wen-xin1   

  1. 1. Aero-Power Sci-Tech Center, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China;2. Navy Aviation Engineering Institute, Yantai 264001, China
  • Received:2004-08-02 Revised:2005-01-12 Online:2006-02-25 Published:2006-02-25

Abstract: Accurate calculation of leakage reactance is key to design of electric machine. The calculation of leakage reactance of dual stator-winding induction generator with excitation regulator is more complex than ordinary 3-phase machine. In this paper, the general mathematic model and equivalent circuit of dual stator-winding induction machine are proposed. The analytical calculations of leakage reactance of dual stator-winding induction machine with different winding structure are presented systematically, the relevant formulas are derived. Finally, a dual stator-winding induction generator with excitation regulator is designed, and its leakage reactance, characteristics and performance are calculated.

Key words: dual stator-winding induction machine, leakage reactance, parameter’s calculation, electric machine design