航空学报 > 2003, Vol. 24 Issue (2): 183-188

变幅载荷下改善焊接接头疲劳性能的超声冲击与TIG熔修方法之比较

王东坡, 霍立兴, 张玉凤, 荆洪阳, 杨新岐   

  1. 天津大学材料科学与工程学院焊接研究所 天津 300072
  • 收稿日期:2002-04-12 修回日期:2002-09-02 出版日期:2003-04-25 发布日期:2003-04-25

Comparison of Ultrasonic Peening Method on Improving the Fatigue Behavior of Welded Joints with TIG Dressing under Variable-Amplitude Load

WANG Dong-po, HUO Li-xing, ZHANG Yu-feng, JING Hong-yang, YANG Xin-qi   

  1. Welding Graduate School; College of Material Science and Engineering; Tianjin University; Tianjin 300072; China
  • Received:2002-04-12 Revised:2002-09-02 Online:2003-04-25 Published:2003-04-25

摘要: 在恒幅和变幅两种加载条件下,对16Mn 钢原始焊态和经过超声冲击及TIG熔修处理的焊接接头进行了对比疲劳试验。结果表明: (1) 在恒幅载荷作用下,TIG熔修试件与焊态试件相比,疲劳强度提高37 %左右,疲劳寿命延长2.5 倍;而在变幅载荷作用下, TIG熔修试件与焊态试件相比,疲劳强度提高34 %左右,疲劳寿命延长1.7~1.9 倍。(2) 在恒幅载荷作用下,超声冲击处理试件与焊态试件相比,疲劳强度提高84 %左右,疲劳寿命延长3.5~27 倍;而在变幅载荷作用下,超声冲击处理试件与焊态试件相比,疲劳强度提高80 %左右,疲劳寿命延长2.5~17 倍。(3) 在低中应力水平、中长寿命区域内,无论是在恒幅载荷作用下还是在变幅载荷作用下,使用超声冲击法提高焊接接头疲劳强度较TIG熔修法的效果更好。

关键词: 变幅载荷, 超声冲击, TIG熔修, 疲劳性能

Abstract: Treated by ultrasonic peening or TIG dressing, the fatigue performance of welded joints and structures isto be improved significantly. This has been verified by many constant amplitude fatigue tests. Subjected to variableamplitude loads, the fatigue performance of the structures will be affected, so that the fatigue contrast tests of 16Mnsteel welded joints with fillet welds in three different conditions : TIG dressing, ultrasonic peening and as weldedcondition were performed. Test results indicated that : (1) Contrasted with the specimens in as welded condition thefatigue strength of the specimens treated by TIG-dressing is increased by about 37 % and the fatigue life is prolongedby 2.5 times when acted by constant amplitude load. When acted by variable amplitude load, contrasted with thespecimens in as welded condition the fatigue strength of the specimens treated by TIG dressing is increased by about34 % and the fatigue life is prolonged by 1.7~1.9 times. (2) When acted by constant amplitude load, contrastedwith the specimens in as welded condition the fatigue strength of the specimens treated by ultrasonic peening is increased by about 84 % and the fatigue life is prolonged by 3.5~27 times. But when acted by variable amplitudeload, contrasted with the specimen in as welded condition the fatigue strength of the specimens treated by ultrasonicpeening is increased by about 80 % and the fatigue life is prolonged by 2.5~17 times; (3) Whether acted by constant amplitude loads or by variable amplitude loads, in the low-medium stress level and medium-long life states theimprovement of fatigue strength of the welded joints created by ultrasonic peening is larger than that created by TIGdressing.

Key words: variable amplitude load, ultrasonic peening, TIG dressing, fatigue performanc e

中图分类号: