航空学报 > 1988, Vol. 9 Issue (4): 188-191

紊流分离过程壁面倒流间歇因子γ_p的测定

方良伟, 李潞龙, 沈振来   

  1. 南京航空学院
  • 收稿日期:1987-06-25 修回日期:1900-01-01 出版日期:1988-04-25 发布日期:1988-04-25

A WALL INTERMITTENT FACTOR γ_p MEASURING SYSTEM FOR USE IN TURBULENT SEPARATING AND REATTACHING FLOWS

Fang Liangwei,Li Lulong, Shen Zhenlai   

  1. Nanjing Aeronautical Institute
  • Received:1987-06-25 Revised:1900-01-01 Online:1988-04-25 Published:1988-04-25

摘要: 本测试系统包括传感甜探头的设计制造,数据采集与处理,标定方法等。 一、三丝探头 图1示出了本测试系统中探头结构外形,其工作原理是先将中间

Abstract: The measurement of the unsteady behavior of nominally two dimensional turbulent flows in regions of separation and reattachment is facilitated by the development of a new measuring system.The features of the system are. 1.The size of the wallflow-direction probe is smaller,the diameter of the probe is only 15mm.2,The probe and its control circuits are all made in China and are relatively inexpensive and easy to construct.3, The measuring accuracy in wall region is higher than the measuring results of using Laser Doppler Anemometer.