Electronics and Control

Asymmetric Operation Performance for Variable Frequency AC Generation System Based on Dual Stator-winding Induction Generator

  • ZHUANG Shenglun ,
  • HUANG Wenxin ,
  • BU Feifei ,
  • SU Ning
Expand
  • College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China

Received date: 2014-01-15

  Revised date: 2014-07-27

  Online published: 2014-08-13

Supported by

National Natural Science Foundation of China (51277095); Aeronautical Science Foundation of China (2012ZC52048)

Abstract

In the variable frequency AC aviation power system, the power system should have the ability to carry the asymmetric load in certain situations. In order to verify the ability of dual stator-winding induction generator (DWIG) variable frequency AC power systems with asymmetric load, a new analysis method of asymmetric operation based on multi-port network load is proposed. First of all, the equivalent circuit of three-phase four-wire asymmetric load is deduced; secondly, the equivalent positive, negative and zero sequence circuit is put forward; thirdly, the asymmetric operation equivalent circuit of DWIG is obtained by combining the above two; finally the output voltage asymmetric degree is precisely calculated by solving the nonlinear equation. The quantitative analysis can be reached by the proposed method, meanwhile, the relationship between motor parameters and output voltage asymmetry is also obtained. The experimental results prove the correctness and effectiveness of the method and verify that DWIG has a good asymmetry load carrying capacity.

Cite this article

ZHUANG Shenglun , HUANG Wenxin , BU Feifei , SU Ning . Asymmetric Operation Performance for Variable Frequency AC Generation System Based on Dual Stator-winding Induction Generator[J]. ACTA AERONAUTICAET ASTRONAUTICA SINICA, 2014 , 35(12) : 3415 -3424 . DOI: 10.7527/S1000-6893.2014.0170

References

[1] Cheng G H. The current situation and development of large civil aircraft power system[J]. Civil Aircraft Design and Research, 2008, 4(1): 1-5. (in Chinese) 程国华. 大型民用飞机电源系统的现状与发展[J]. 民用飞机设计与研究, 2008, 4(1): 1-5.

[2] Bansal R C, Bhatti T S, Kothari D P. Bibliography on the application of induction generators in nonconventional energy systems[J]. IEEE Transactions on Energy Conversion, 2003, 18(3): 433-439.

[3] Elbuluk M, Kankan M. Potential starter/generator technologies for future aerospace applications[J]. IEEE Aerospace and Electronic Systems Magazine, 1997, 12(5): 24-31.

[4] Alan I, Lipo T A. Starter/generator employing resonant- converter-fed induction machine part I analysis[J]. IEEE Aerospace and Electronic Systems Magazine, 2000, 36(4): 1309-1318.

[5] Leidhold R, Garcia G, Valla M. Induction generator controller based on the instantaneous reactive power theory[J]. IEEE Transactions on Energy Conversion, 2002, 17(3): 368-373.

[6] Hu Y W, Huang W X, Zhang L H. Research on employing starter/generator system[J]. Transactions of China Electrotechnical Society, 2006, 21(5): 7-13. (in Chinese) 胡育文, 黄文新, 张兰红. 异步电机起动/发电系统的研究[J]. 电工技术学报, 2006, 21(5): 7-13.

[7] Ojo O, Davidson I. PWM-VSI inverter-assisted stand-alone dual stator winding induction generator[J]. IEEE Transactions on Industry Applications, 2000, 36(6): 1604-1611.

[8] Bu F F, Huang W X, Hu Y W, et al. A stand-alone dual stator-winding induction generator variable frequency AC power system[J]. IEEE Transactions on Power Electronics, 2012, 27(1): 10-13.

[9] Liu L S, Hu Y W, Huang W X. Optimal design of dual stator-winding induction generator operating with variable speed[J]. Proceedings of the CSEE, 2006, 26(3): 125-130. (in Chinese) 刘陵顺, 胡育文, 黄文新. 变速运行的双绕组感应发电机电磁优化设计[J]. 中国电机工程学报, 2006, 26(3):125-130.

[10] Sun Y P. Single phase asynchronous motor and its application[M]. Beijing: China Machine Press, 1987: 16-38. (in Chinese) 孙云鹏. 单相异步电动机及其应用[M]. 北京:机械工业出版社, 1987: 16-38.

[11] Ouazene L, Mcpherson G L. Analysis of the isolated induction generator[J]. IEEE Transactions on Power Apparatus and Systems, 1983, 102(8): 2793-2798.

[12] Malik N H, Haque S E. Steady-state analysis and performance of an isolated self-excited inductions generator[J]. IEEE Transactions on Energy Conversion, 1986, 1(3): 134-139.

[13] Chan T F, Lai L L. Steady-state analysis and performance of a stand-alone three-phase induction generator with asymmetrically connected load impedances and excitation capacitances[J]. IEEE Transactions on Energy Conversion, 2011, 16(4): 327-333.

[14] Hao K S. Terminal voltage stability analysis of self-excited induction generator[D]. Qingdao: Qingdao University, 2007. (in Chinese) 郝宽胜. 独立运行异步发电机电压稳定性的研究[D].青岛:青岛大学, 2007.

[15] Zhang D M. Self-excited three phrase induction generator steady-state analysis with single phrase load[D]. Qingdao: Qingdao University, 2006. (in Chinese) 张冬梅. 自激式三相异步发电机单相负载运行稳态分析[D]. 青岛:青岛大学, 2006.

[16] Wei X M. Asymmetric operation research of three phrase induction generator[D]. Qingdao: Qingdao University, 2011. (in Chinese) 魏雪敏. 三相异步发电机不对称运行的研究[D]. 青岛:青岛大学, 2011.

Outlines

/