基于歧管微通道的航空燃油高效换热技术研究-飞行器能源生成与多能利用

  • 王重 ,
  • 吴谋彬 ,
  • 孙京川 ,
  • 董苯思 ,
  • 张丽娜 ,
  • 焦兴育
展开
  • 1. 北京航空航天大学
    2. 中国航发湖南动力机械研究所

收稿日期: 2026-04-27

  修回日期: 2026-10-13

  网络出版日期: 2026-10-19

Research on Efficient Heat Transfer Technology of Aviation Fuel Based on Manifold Microchannels

  • WANG Zhong ,
  • WU Mou-Bin ,
  • SUN Jing-Chuan ,
  • DONG Ben-Si ,
  • ZHANG Li-Na ,
  • JIAO Xing-Yu
Expand

Received date: 2026-04-27

  Revised date: 2026-10-13

  Online published: 2026-10-19

摘要

针对先进飞行器高功率密度机载电子设备非均匀热负荷下局部热点突出,以及强化换热与流动阻力难以兼顾的问题,以超临界RP-3航空燃油为冷却工质,建立非均匀热源条件下歧管微通道三维数值模型,研究歧管宽高比、微通道宽高比、微通道间距及质量流率对温度响应、传热性能和水力性能的影响,并在全局结构参数优化基础上进一步开展热点邻域歧管间距定向调控。结果表明:歧管与微通道宽高比均为1∶1时,传热强化与流动损失匹配较优;微通道间距存在最佳设计区间,最优值位于0.1 mm附近,0.05–0.3 mm范围内综合性能保持较优。针对最高热流密度区域实施局部调控后,热点位置歧管间距由1.0 mm减小至0.35 mm,可使微通道支路的速度变异系数由53.44%降至10.27%,基板最高温度降低3.37 ℃,热点温差降低20.45%;间距继续减小至0.20 mm时,局部对流换热能力下降,最高温度反而升高。研究表明,歧管微通道对非均匀热源的强化冷却不仅取决于整体几何参数,还受微通道支路流量分配均匀性与局部换热强度协同作用的影响,研究结果可为航空燃油热管理中高热流电子设备的分区强化冷却与歧管微通道结构设计提供依据。

本文引用格式

王重 , 吴谋彬 , 孙京川 , 董苯思 , 张丽娜 , 焦兴育 . 基于歧管微通道的航空燃油高效换热技术研究-飞行器能源生成与多能利用[J]. 航空学报, 0 : 1 -0 . DOI: 10.7527/S1000-6893.2026.33777

Abstract

To address the pronounced local hotspots induced by non-uniform thermal loads in high-power-density airborne elec-tronic equipment, as well as the inherent trade-off between heat-transfer enhancement and flow resistance, a three-dimensional numerical model of a manifold microchannel heat sink using supercritical RP-3 aviation kerosene as the coolant was established under non-uniform heat-source conditions. The effects of manifold aspect ratio, microchannel aspect ratio, microchannel spacing, and mass flow rate on the thermal response, heat-transfer performance, and hy-draulic characteristics were systematically investigated. Based on the global optimization of structural parameters, tar-geted regulation of the manifold spacing in the vicinity of the hotspot was further performed. The results show that an aspect ratio of 1:1 for both the manifold and microchannel provides a favorable balance between heat-transfer en-hancement and flow loss. An optimal design range exists for the microchannel spacing, with the best overall thermo-hydraulic performance obtained at approximately 0.1 mm and consistently favorable performance maintained within 0.05–0.3 mm. After local regulation was applied to the region with the highest heat flux, reducing the manifold spacing near the hotspot from 1.0 mm to 0.35 mm decreased the velocity coefficient of variation among the microchannel branches from 53.44% to 10.27%, reduced the maximum substrate temperature by 3.37 °C, and decreased the hotspot temperature difference by 20.45%. Further decreasing the spacing to 0.20 mm weakened the local convective heat-transfer capability and instead resulted in an increase in the maximum temperature. These results demonstrate that the enhanced cooling performance of manifold microchannels under non-uniform heat-source conditions is gov-erned not only by the global geometric parameters, but also by the synergistic effects of flow-distribution uniformity among microchannel branches and local heat-transfer intensity. The present study provides a theoretical basis for zonal cooling enhancement and manifold microchannel design for high-heat-flux electronic equipment in aircraft fuel thermal-management systems.