二氧化碳ECR离子推力器性能计算与实验对比-空间电推进关键技术专栏

  • 杨云帆 ,
  • 聂万胜 ,
  • 李丹阳 ,
  • 袁姝蕙 ,
  • 王梓桐 ,
  • 周思引 ,
  • 朱康武
展开
  • 1. 航天工程大学
    2. 装备学院
    3. 中国人民解放军军事航天部队航天工程大学
    4. 上海交通大学

收稿日期: 2026-07-02

  修回日期: 2026-09-13

  网络出版日期: 2026-09-28

Comparison of calculated and experimental performance of the carbon dioxide ECR ion thruster

  • YANG Yun-Fan ,
  • NIE Wan-Sheng ,
  • LI Dan-Yang ,
  • YUAN Shu-Hui ,
  • WANG Zi-Tong ,
  • ZHOU Si-Yin ,
  • ZHU Kang-Wu
Expand

Received date: 2026-07-02

  Revised date: 2026-09-13

  Online published: 2026-09-28

摘要

针对未来空间任务对原位资源利用的需求,开展以二氧化碳为工质的电子回旋共振(Electron cyclotron resonance,ECR)离子推力器的性能计算与实验研究。设计了一款适用于二氧化碳工质的5 cm口径ECR离子推力器,建立了二氧化碳工质ECR离子推力器的全局模型并计算其性能参数,搭建了包含推力测量装置和E×B探针的实验系统,开展二氧化碳工质ECR离子推力器性能实验,并将实验结果与计算结果进行对比分析。研究结果表明,二氧化碳放电等离子体中主要产物为CO2+离子,同时存在CO+、O+和C+等解离电离产物。在二氧化碳质量流率为0.11 mg/s,30 W输入微波功率条件下,离子束流和推力的计算最大值分别为56.7 mA和2.1 mN,对应实验最大值分别为46.2 mA和1.73 mN;在二氧化碳质量流率为0.09 mg/s,30 W输入微波功率条件下,比冲计算最大值为2210.3 s,对应实验最大值为1906 s,性能计算值与实验值的相对误差均小于25%。全局模型能较好地反映二氧化碳放电体系中多组分电离与解离并存的基本特征,二氧化碳分子复杂的激发和解离反应通道是导致其放电损耗较高、推进剂利用率偏低的主要原因。

本文引用格式

杨云帆 , 聂万胜 , 李丹阳 , 袁姝蕙 , 王梓桐 , 周思引 , 朱康武 . 二氧化碳ECR离子推力器性能计算与实验对比-空间电推进关键技术专栏[J]. 航空学报, 0 : 1 -0 . DOI: 10.7527/S1000-6893.2026.34211

Abstract

To address the demand for in-situ resource utilization (ISRU) in future space missions, this work presents a combined computational and experimental study on the performance of an electron cyclotron resonance (ECR) ion thruster using carbon dioxide (CO2) as propellant. A 5 cm diameter ECR ion thruster specifically designed for CO2 operation was developed. A global model was established to calculate the thruster performance parameters, and an experimental system equipped with a thrust measurement stand and an E×B probe was constructed to conduct performance tests. The experimental results were compared with the calculated values. The results show that the dominant ion species in the CO2 discharge plasma is CO2+, along with dissociative ionization products including CO+, O+, and C+. At a CO2 mass flow rate of 0.11 mg/s and an input microwave power of 30 W, the calculated maximum ion beam current and thrust are 56.7 mA and 2.1 mN, respectively, while the corresponding experimental maxima are 46.2 mA and 1.73 mN. At a mass flow rate of 0.09 mg/s and 30 W microwave power, the calculated maximum specific impulse is 2210.3 s, with an experimental maximum of 1906 s. The relative errors between the calculated and experimental performance values are all within 25%. The global model effectively captures the essential features of the CO2 discharge system, where multi-component ionization and dissociation coexist. The complex excitation and dissociative reaction pathways of CO2 molecules are identified as the primary reasons for the relatively high discharge loss and low propellant utilization efficiency.
Options
文章导航

/

〈 〉