压力敏感涂料特性及其校准技术实验研究
收稿日期: 2012-02-23
修回日期: 2012-05-07
网络出版日期: 2012-06-07
基金资助
国家自然科学基金(11172316)
Experimental Research of Pressure Sensitive Paint Performance and Calibration Technique
Received date: 2012-02-23
Revised date: 2012-05-07
Online published: 2012-06-07
Supported by
National Natural Science Foundation of China (11172316)
精细化的校准技术和涂料特性研究是影响压力敏感涂料(PSP)测量技术测量精度及其工程应用的重要因素。为此以PSP地面实验测量系统为主要平台,进行了国产PSP的静态校准和光降解实验,基于自主编制的PSP静态校准图像后处理程序研究了PSP压力、温度灵敏度之外所展现出的重要特性。研究结果表明:一定压力范围内,PSP的Stern-Volmer响应曲线呈现出较为明显的非线性,在校准中应采取高阶Stern-Volmer关系式进行拟合;在均匀压力和温度下,不同样片区域的校准结果呈现出空间不均匀性,这种不均匀性会影响PSP的校准精度;PSP存在光降解效应,其降解曲线在一定时间内近似为线性。同时,本文还简要分析了其产生机理以及对PSP测量精度的影响,初步提出了相应的评估指标及改进措施。
李国帅 , 周强 , 刘祥 , 金毕青 , 高丽敏 , 马护生 , 熊健 . 压力敏感涂料特性及其校准技术实验研究[J]. 航空学报, 2013 , 34(2) : 227 -234 . DOI: 10.7527/S1000-6893.2013.0026
Calibration technique and paint performance research are critical for improving the measurement accuracy and engineering application of pressure sensitive paint (PSP). In this paper, static calibration and photo-degradation experiments are performed based on a PSP static calibration setup and image post-processing software which is programmed independently to study paint performances other than its pressure and temperature sensitivity. The results of this study reveal that the Stern-Volmer curve of PSP exhibits a nonlinear characteristic rather than following the conventional linear pattern, which is approximated with an polynomial function using curve-fitting analysis. Moreover, calibration results of the painted coupon vary in space although the experiment is performed under uniform pressure and temperature,and it tends to decrease calibration accuracy. Finally, PSP demonstrates a photo-degradation characteristic and the degradation curve is approximately linear within a range of time. Evaluation indices of pressure response nonlinearity, calibration spatial non-uniformity and photo-degradation are proposed while their mechanims of production, influences on PSP measurement accuracy and correction methods are also presented.
[1] Morris M J, Donovan J F, Kegelman J T, et al. Aerodynamic application of pressure-sensitive paint. AIAA Journal, 1993, 31(3): 415-419.
[2] Kontis K. A review of some current research on pressure sensitive paint and thermographic phosphor techniques. The Aeronautical Journal, 2007, 7(1): 495-508.
[3] Engler R H, Klein C. DLR PSP system intensity and lifetime measurements. Instrumentation in Aerospace Simulation Facilities, 1997, 29(2): 46-56.
[4] Erickson G E, Gonzalez H A. Wind tunnel application of a pressure-sensitive paint technique to a double delta wing model at subsonic and transonic speeds. NASA/TM, 2006, 32(5): 41-47.
[5] Fang S, Long S R, Disotell K J, et al. Comparison of unsteady pressure-sensitive pain measurement techniques. AIAA Journal, 2012, 50(1): 109-122.
[6] Mitsuo K, Kurita M, Fujii K, et al. PSP measurement of a high-lift-device model in JAXA 6.5 m×5.5 m low-speed wind tunnel. AIAA-2007-1356, 2007.
[7] Ouchi H, Irikado T. PSP Measurements in the large-scale transonic wind tunnel and associated image data processing. AIAA-2005-1079, 2005.
[8] Zhang Y C, Chen L S, Yan L, et al. Investigation and application of pressure sensitive paint techniques in wind tunnel test. Journal of Experiment in Fluid Mechanics, 2010, 24(1): 74-78. (in Chinese) 张永存, 陈柳生, 阎莉, 等. 压敏涂料技术在风洞中的应用研究. 实验流体力学, 2010, 24(1): 74-78.
[9] Zhang Y C, Chen L S, Ma X G, et al. Investigation and application of two-component pressure sensitive paint techniques. Acta Aerodynamic Sinica, 2010, 28(5): 485- 489.(in Chinese) 张永存, 陈柳生, 马晓光, 等. 双分量压敏涂料技术的应用研究. 空气动力学报, 2010, 28(5): 485-489.
[10] Zhou Q, Liu B, Gao L M, et al. Pressure measurement on suction surface of a single vane using pressure-sensitive paint. Chinese Journal of Aeronautics, 2009,22(2): 138-144.
[11] Xiang X J, Lang W D, Xiong H L, et al. Application of pressure-sensitive paint on aerodynamics load measurement of delta wing model in supersonic wind tunnel. Journal of Experiment in Fluid Mechanics, 2010, 24(3): 81-86. (in Chinese) 向星居, 郎卫东, 熊红亮, 等. 压敏漆测量三角翼模型气动载荷的超声速风洞试验. 实验流体力学, 2010, 24(3): 81-86.
[12] Muller J A. Calibration to determine pressure and temperature sensitivities of a pressure-sensitive paint. ADA380715, 2000.
[13] Benic T J. Calibration of detection angle for full field pressure sensitive paint measurement. AIAA-2001-307, 2001.
[14] Orozco G, Kontis K. Effects of filters on the performance and characteristics of pressure sensitive paints. Measurement Science and Technology, 2009, 7(20): 1-6.
[15] Ruyten W, Chall C. Spatially nonuniform self-quenching of the pressure-sensitive paint PtTFPP/FIB. AIAA-2009-1006, 2009.
[16] Woodmansee M A, Dutton J C. Treating temperature-sensitivity effects of pressure-sensitive paint measurements. Experiments in Fluids, 1998, 24(2): 163-174.
[17] Dhall T, Chall C. Pressure resolution of a PSP based measurement system with non-linear intensity response. AIAA-2008-279, 2008.
[18] Benn E, Mark E, John D, et al. General strategy for the development of an improved pressure-sensitive paint formulation. AIAA-2002-1127, 2002.
[19] Liu B, Zhou Q, Zheng L X, et al. Construction of pressure-sensitive paint measurement system and calibration for homemade fluorescent pressure-sensitive paint. Journal of Air Force Engineering University, 2007, 6(8): 72-75. (in Chinese) 刘波, 周强, 郑立新, 等. 压力敏感涂料测量系统及涂料校准实验. 空军工程大学学报, 2007, 6(8): 72-75.
[20] Gao L M, Wang H, Liu B, et al. Experimental of study influence of measurement system characteristics on pressure-sensitive paint. Acta Aeronautica et Astronautica Sinica, 2010, 31(1): 76-81. (in Chinese) 高丽敏, 王欢, 刘波, 等. 测量系统特性对压敏涂料校准影响的实验研究. 航空学报, 2010, 31(1): 76-81.
[21] Huber J P, Carroll B F. Application of dual sorption theory to pressure sensitive paints. AIAA Journal, 1997, 35(11): 1790-1792.
/
〈 |
|
〉 |