The accuracy of spatial calibration in Stereo Particle Image Velocimetry (SPIV) has a great influence on the accuracy of the velocity measurement. In order to study the ability of various calibration model to deal with input error, a dimensionless parameter, namely, error attenuation coefficient, is defined to evaluate the response of spatial calibration model to input error. Based on this error attenua-tion coefficient, the error propagation characteristics of conventional spatial calibration model, including polynomial model and cam-era pinhole model, can be evaluated quantitatively. A neural network-based space calibration model is then developed. This new mod-el is naturally adaptive to multiple-camera joint calibration, which is lacked by conventional calibration models, thus is suitable for SPIV. Using synthetic experiment, it is demonstrated that this neural network model has the ability of suppressing the propagation of the input error in a large measurement parameter space, which are not posed by polynomial model or pinhole model. Additionally, it outbids traditional models in the scenario of high optical distortion. Therefore, this neural network model might be an ideal candidate for the spatial calibration of SPIV. Finally, it is confirmed in the experiment that the error of neural network calibration model is only a quarter of that of traditional model.
DOU Jian-Yu
,
PAN Chong
. Spatial calibration model of stereo PIV based on Neural Network[J]. ACTA AERONAUTICAET ASTRONAUTICA SINICA, 0
: 0
-0
.
DOI: 10.7527/S1000-68932020.24720
[1]Lecerf A, Renou B, Allano D, et al.Stereoscopic PIV: validation and application to an isotropic turbulent flow[J].Experiments in Fluids, 1999, 26(1-2):107-115
[2]Steven, J, Beresh.Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel[J].Experiments in Fluids, 2016, 57(48):1-17
[3]陈钊, 郭永彩, 高潮.三维原理及其实现方法[J].实验流体力学, 2006, 20(4):77-82
[4]Wieneke B.Stereo-PIV using self-calibration on particle images[J].Experiments in Fluids, 2005, 39(2):267-280
[5]S M Soloff, R J Adrian, ZC Liu.Distortion compensa-tion for generalized stereoscopic particle image veloci-metry[J].Measurement ence & Technology, 1997, 8(12):1441-1454
[6]Fei R, Merzkirch W.Investigations of the meas-urement accuracy of stereo particle image velocimetry[J].Experiments in Fluids, 2004, 37(4):559-565
[7]张烁, 燕丹晨, 甄莹, 等.利用线性变换和后方交会的月球车相机标定[J].测绘科学, 2015, 209(11):29-33
[8]陈启刚, 钟强.体视粒子图像测速技术研究进展[J].水力发电学报, 2018, 193(08):40-56
[9]Stanislas M, Okamoto K, Khler C J, et al.Main results of the third international PIV Challenge[J].Exper-iments in Fluids, 2008, 45(1):27-71
[10]Calluaud D, David L.BACKWARD PROJECTION ALGORITHM AND STEREOSCOPIC PARTICLE IMAGE VELOCIMETRY MEASUREMENTS OF THE FLOW AROUND A SQUARE SECTION CYLINDER[C]// 11th Int. Symposium on Applications of Laser techniques to Fluid Mechanics. 2002.
[11]Calluaud D, David L.Stereoscopic particle image veloc-imetry measurements of the flow around a surface-mounted block[J].Experiments in Fluids, 2004, 36(1):53-61
[12]Scarano F, David L, Bsibsi M, et al.S-PIV com-parative assessment: image dewarping+misalignment correction adn pinhole+geometric back projection[J].Ex-periments in Fluids, 2005, 39(2):257-266
[13]Westerweel J.Theoretical analysis of the measurement precision in particle image velocimetry[J].Experiments in Fluids, 2000, 29(1 Supplement):S003-S012
[14]Prasad A K.Stereoscopic particle image velocimetry[J].Experiments in Fluids, 2000, 29(2):103-116
[15]Lawson N J, Wu J.Three-dimensional particle image velocimetry: error analysis of stereoscopic tech-niques[J].Measurement ence & Technology, 1997, 8(8):894-894
[16]邱思逸, 程泽鹏, 向阳, 等.基于线性稳定性分析的翼尖涡摇摆机制[J]. 航空学报, 2018, 40(8).[J].航空学报, 2018, 40(8):1-4
[17]Coudert S J M, Schon J P.Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV[J].Measurement ence and Technology, 2001, 12(9):1371-1371
[18]Giordano R, Astarita T.Spatial resolution of the Stereo PIV technique[J].Experiments in Fluids, 2009, 46(4):643-658
[19]Prasad A K, Adrian R J.Stereoscopic particle image ve-locimetry applied to liquid flows[J].Experiments in Flu-ids, 1993, 15(1):49-60
[20]史泽林, 康娇, 孙锐.基于神经网络的大视场成像畸变校正方法[J].光学精密工程, 2005, 13(003):348-353
[21]田立坤, 刘晓宏, 李洁.神经网络用于大视场显示设备的畸变校正[J].电光与控制, 2012, 019(012):43-46
[22]Prasad, a K, Jensen, K.Scheimpflug stereocamera for particle image velocimetry in liquid flows[J].Applied Optics, 1995, 34(30):7092-9