航空学报 > 2013, Vol. 34 Issue (11): 2472-2481   doi: 10.7527/S1000-6893.2013.0210

多排反向射流角气膜冷却特性研究

丁阳1, 常海萍1, 杜治能2   

  1. 1. 南京航空航天大学 能源与动力学院, 江苏 南京 210016;
    2. 中航工业沈阳发动机设计研究所, 辽宁 沈阳 110015
  • 收稿日期:2013-01-08 修回日期:2013-04-02 出版日期:2013-11-25 发布日期:2013-04-26
  • 通讯作者: 常海萍,Tel.:025-84892201-2312 E-mail:chppe@nuaa.edu.cn E-mail:chppe@nuaa.edu.cn
  • 作者简介:丁阳 男,博士研究生。主要研究方向:航空发动机传热。 Tel:025-84892201-2608 E-mail:dy02jx006@163.com;常海萍 女,教授,博士生导师。主要研究方向:航空发动机传热。 Tel:025-84892201-2312 E-mail:chppe@nuaa.edu.cn;杜治能 男,高级工程师。主要研究方向:航空发动机传热。 Tel:024-24287495
  • 基金资助:

    省部级项目

Investigation on Characteristics of Multiple Rows of Opposite Lateral Ejection Angle Film Cooling

DING Yang1, CHANG Haiping1, DU Zhineng2   

  1. 1. College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China;
    2. AVIC Shenyang Aeroengine Design and Research Institute, Shenyang 110015, China
  • Received:2013-01-08 Revised:2013-04-02 Online:2013-11-25 Published:2013-04-26
  • Supported by:

    Province Level Project

摘要:

借助正交试验对具有多排反向射流角气膜冷却结构的冷却特性进行了研究分析,采用Realizable k-ε湍流模型和速度分布两层模型进行模拟计算,研究了横向射流角β、开孔率F、长宽比S/P以及吹风比M对冷却特性的影响,并分析了其影响机理。研究结果表明:与单排双射流结构相比,多排反向射流角结构虽然涡量分布不对称,但是依靠持续的冷气注入来维持反向涡对,也可以得到理想的冷却效果。在试验参数范围内,对平均冷却效率影响程度由高到低依次为:开孔率,吹风比,长宽比,横向射流角。对平均对流换热系数影响程度由高到低依次为:吹风比,开孔率,横向射流角,长宽比。综合考虑冷却效率和换热特性,较优的结构与流动参数为β=55°、M=1.2、F=2%、S/P=1.4。

关键词: 正交试验, 冷却, 横向射流角, 冷却效率, 换热系数

Abstract:

An investigation on the cooling characteristics of multiple rows of opposite lateral ejection angle film cooling is conducted by means of an orthogonal numerical simulation test. The numerical simulation is conducted by a Realizable k-ε turbulent model and a two-layer velocity zonal model using commercial numerical calculation software. The purpose of the investigation is to reveal the influence of such parameters as lateral ejection angle β, orifice coefficient F, length to width ratio S/P and blowing ratio M, on film cooling. Besides, this paper also tries to find how the above parameters act on cooling respectively. The results show that, compared with the classical counter-rotating vortex pair which appears in the flow field of double-jet film cooling, the vortex pair structure in the downstream of the film-outlet of multiple-rows of opposite lateral ejection angle film cooling is asymmetrical, and cooling is maintained by ejecting cooling jets through rows of holes continuously. It is worth noting that this structure of film cooling achieves excellent cooling effect. The orifice coefficient is found to have the greatest impact on average film cooling effectiveness. Descending order of other parameters, based on their impacts on the average film cooling effectiveness, is: blowing ratio, length to width ratio, and lateral ejection angle, while descending order of the parameters, based on their influence on the heat transfer, is: β=55, M=1.2, F=2%, S/P=1.4.

Key words: orthogonal test, cooling, lateral ejection angle, film cooling effectiveness, heat transfer coefficient

中图分类号: